Danial Qadir, Teeside University, was awarded funding in the UKCCSRC’s Focused Funding 2026 call to look at “ A Marker-Based Framework for Wastewater Treatment Decision Making in Amine Based Capture Plants”.
Carbon capture is a key to reducing industrial carbon dioxide emissions. Among other techniques, amine solvents, such as monoethanolamine (MEA) or blended amines, absorb CO2 from flue gas. These solvents can be effective, but the capture process also creates wastewater streams that must be managed safely. This wastewater is not just ordinary wastewater. It contains leftover solvent, solvent degradation products, ammonia, organic acids, heat-stable salts and trace hazardous compounds such as nitrosamines and nitramines. These substances may come from solvent ageing, reaction with oxygen, sulphur and nitrogen oxides in the flue gas, or from high-temperature solvent management steps such as reclaiming.

The problem: too much chemistry, not enough decision support
A technical report or research paper may list many different impurities in amine-capture wastewater. For a plant designer, operator or regulator, the practical question is different: what do these measurements mean for treatment? Should the stream go to biological treatment? Does it need advanced oxidation? Should it be segregated and sent off site? Is more monitoring needed before a decision can be made?
Experienced engineers may already recognise some of these patterns. For example, reclaimer waste is expected to be concentrated and difficult to treat, while washwater may be more dilute but can carry trace hazardous degradation products. The challenge is that this knowledge is often held as expert judgement rather than as a transparent, repeatable decision method.
What is a marker-based framework?
The framework developed in this project uses selected “markers” instead of trying to treat every impurity as a separate decision point. A marker is a measurable compound or parameter that represents a wider wastewater burden. In simple terms, a marker helps translate a laboratory result into a treatment decision.
For example, chemical oxygen demand (COD), total organic carbon (TOC) and biological oxygen demand (BOD) are not individual pollutants. They are bulk markers for organic load and biodegradability. Ammonia and total nitrogen indicate nitrogen burden. Organic acids and heat-stable salt anions indicate salt and ionic burden. Nitrosamines and nitramines are used as high-concern amine degradation product markers because they indicate the need for targeted hazard control.
How the framework works
The decision process starts with stream identity. Wastewater from a carbon capture plant can come from water-wash systems, reclaimer waste, condensate, blowdown, solvent purge, acid-wash liquor or mixed drains. The same marker can have a different meaning depending on the stream. Moderate organic load in washwater may be manageable, while high organic load in reclaimer waste may indicate a strong, inhibitory and salt-rich stream.
The second step is to assess marker classes. The framework looks at nitrogen burden, biodegradability, hazardous amine degradation products and ionic or heat-stable salt burden. It then maps these findings to treatment functions. These functions are grouped into five categories: feed conditioning, biological treatment, physico-chemical pretreatment, targeted polishing, and segregation/recovery/off-site management.
The output is not a final process design. It is an early-stage treatment route. For example, a washwater stream with nitrosamines or nitramines may be routed towards feed conditioning followed by advanced oxidation and polishing. A high-strength reclaimer waste may need segregation, equalisation, biological feasibility testing and concentrate or salt management.
Why this is useful
The framework is useful because early carbon capture projects often do not have complete effluent datasets. At front-end design stage, a developer may know that a reclaimer or washwater system will exist, but may not yet know full concentrations of COD, BOD, ammonia, heat-stable salts or trace degradation products. The framework helps identify what should be measured first and what treatment functions are likely to be needed.
It also makes decisions easier to explain. Rather than saying that a treatment has been selected because it is generally suitable, the framework shows which marker caused the decision. High biodegradable organic load points towards biological treatment. Nitrosamines or nitramines trigger targeted destruction and polishing. High heat-stable salts or conductivity point towards ionic or concentrate management. Missing data are not ignored; they are flagged as gaps that must be filled before detailed design.

What the framework does not claim
This framework does not replace site-specific wastewater testing, pilot trials or detailed engineering design. It does not set discharge limits, and it does not claim that one technology will work for every plant. Instead, it acts as a screening and communication tool. It organises evidence from literature, reports and plant examples into a practical structure that can be used by researchers, engineers, funders, operators and regulators.
The main value is therefore not that it discovers entirely new treatment technology. Its value is that it offers an evidence-based, repeatable route for early decision-making. This is especially important as more carbon capture projects move from research into real industrial deployment.
The take-home message
Amine-based carbon capture can help reduce industrial CO2 emissions, but its wastewater must be understood and managed properly. A marker-based framework provides a simple way to move from complex chemistry to practical treatment decisions. By linking stream type, marker burden and treatment function, it helps ensure that important risks such as solvent ageing, salt build-up and hazardous degradation products are considered early, before full plant design is locked in.
In short, the framework turns wastewater analysis into an early-stage treatment route by using selected markers that represent organic load, nitrogen burden, hazardous degradation products and salt/ionic burden.